CERN Accélérateur de science

CMS Note
Report number CMS-CR-2009-156
Title The CMS Electromagnetic Calorimeter detector control and monitoring system
Author(s) Hintz, W (Zurich, ETH)
Collaboration on behalf of the CMS ECAL group
Publication 2010
Imprint 27 May 2009
Number of pages 3
In: Nucl. Instrum. Methods Phys. Res., A 617 (2010) 269-271
In: 11th Pisa Meeting on Advanced Detectors on Frontier Detectors For Frontier Physics, La Biodola, Italy, 24 - 30 May 2009, pp.269-271
DOI 10.1016/j.nima.2009.06.090
Subject category Detectors and Experimental Techniques
Accelerator/Facility, Experiment CERN LHC ; CMS
Free keywords ECAL ; DETECT-INTEG ; ELECTRONICS
Abstract The Electromagnetic Calorimeter of the CMS experiment at the LHC is made of 75848 lead tungstate scintillating crystals and photo-detectors. In order to ensure the design stability and precision, the detector's properties must be continuously monitored. The tests to determine the performance of the detector's crystals, photo detectors and readout electronics are presented in detail. In particular, the identification of different hardware problems that were found is discussed as well as on their development in time.
Copyright/License Preprint: (License: CC-BY-4.0)

Corresponding record in: Inspire


 Notice créée le 2009-08-13, modifiée le 2018-06-07


Fichiers:
Télécharger le document
PDF