| Главная страница > CERN R&D Projects > CERN Detector R&D Projects > CALICE > CALICE Papers > Particle Identification with Cherenkov detectors in the 2011 CALICE Tungsten Analog Hadronic Calorimeter Test Beam at the CERN SPS |
| Report number | LCD-Note-2013-006 ; AIDA-NOTE-2015-012 |
| Title | Particle Identification with Cherenkov detectors in the 2011 CALICE Tungsten Analog Hadronic Calorimeter Test Beam at the CERN SPS |
| Author(s) | Dannheim, D (CERN) ; Elsener, K (CERN) ; Klempt, W (CERN) ; Lucaci Timoce, A (CERN) ; van der Kraaij, E (Bergen U.) |
| Publication | 2013 |
| Collaboration | CERN Linear Collider Detector collaboration |
| Imprint | 2013-06-19 |
| Number of pages | 19 |
| Subject category | Detectors and Experimental Techniques ; 6: Transnational access CERN ; 6.1: Access to CERN-Test-beams |
| Accelerator/Facility, Experiment | CERN Linear Collider Detector CALICE CERN SPS |
| Abstract | In 2011 the CALICE Tungsten Analog Hadronic Calorimeter prototype (W-AHCAL) was exposed to mixed beams of electrons, pions, kaons and protons with momenta from 10 to 300 GeV in the CERN SPS H8 beam line. The selection of pion, kaon and proton samples is based on the information obtained from two Cherenkov threshold counters. This note presents the strategy for the particle identification, as well as the calibration, operation and analysis of the Cherenkov counters. Efficiency and sample-purity estimates are given for the data selected for the W-AHCAL data analysis. |
| Other source | Inspire |
| Submitted by | dieter.schlatter@cern.ch |