<?xml version="1.0" encoding="UTF-8"?>
<references>
<reference>
  <a1>Rousset, Bernard</a1>
  <a2>Claudet, Gerard</a2>
  <a2>Gauthier, Alain</a2>
  <a2>Seyfert, Peter</a2>
  <a2>Martinez, Andre</a2>
  <a2>Lebrun, Philippe</a2>
  <a2>Marquet, Michel</a2>
  <a2>Van Weelderen, Rob</a2>
  <t1>Pressure drop and transient heat transport in forced flow single phase helium II at high Reynoldsnumbers</t1>
  <t2>Cryogenics</t2>
  <sn/>
  <op>317-320</op>
  <vo>34</vo>
  <ab>Pressure drop and transient heat transport measurements had been performed in the superfluid helium test loop at CEA/CEN-Grenoble, France. Single phase helium II was circulated through a 28 mm I.D. tube, over a length of 200 m for mass flow rates between 0.02 and 0.1 kg/s. Steady-state pressure drop measurements allow us to estimate the friction factor for Reynolds numbers in the 106 range. Rectangular heat pulses were applied at mid-length, and the fluid temperature was measured at several locations along the flow, upstream and downstream. A code has been developed which uses the two-fluid model to simulate time-dependent heat transport helium 11 flow. Simulation results are in good agreement with experimental measurements.</ab>
  <la>eng</la>
  <k1/>
  <pb/>
  <pp/>
  <yr>1994</yr>
  <ed/>
  <ul/>
  <no>Imported from Invenio.</no>
</reference>

</references>