<dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:invenio="http://invenio-software.org/elements/1.0" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd"><dc:language>eng</dc:language><dc:creator>Arpaia, P</dc:creator><dc:creator>Giloteaux, D</dc:creator><dc:creator>Lucariello, G</dc:creator><dc:creator>Spiezia, G</dc:creator><dc:title>Uncertainty Reduction Via Parameter Design of A Fast Digital Integrator for Magnetic Field Measurement</dc:title><dc:subject>Accelerators and Storage Rings</dc:subject><dc:identifier>CERN-AT-2007-025-MTM</dc:identifier><dc:description>At European Centre of Nuclear Research (CERN), within the new Large Hadron Collider (LHC) project, measurements of magnetic flux with uncertainty of 10 ppm at a few of decades of Hz for several minutes are required. With this aim, a new Fast Digital Integrator (FDI) has been developed in cooperation with University of Sannio, Italy [1]. This paper deals with the final design tuning for achieving target uncertainty by means of experimental statistical parameter design.</dc:description><dc:publisher/><dc:date>2007-08-30</dc:date><dc:source>http://cds.cern.ch/record/1092659</dc:source><dc:identifier>http://cds.cern.ch/record/1092659</dc:identifier><dc:identifier>oai:cds.cern.ch:1092659</dc:identifier><invenio:conference.notes>revised version submitted on 2008-03-05 14:45:48</invenio:conference.notes><invenio:conference.notes>Not published in the proceedings</invenio:conference.notes></dc:dc>