<?xml version="1.0" encoding="UTF-8"?>
<xml>
<records>
<record>
  <contributors/>
  <titles>
    <title>Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full - Part 1: General principles and requirements</title>
    <secondary-title/>
  </titles>
  <doi/>
  <pages/>
  <volume/>
  <number/>
  <dates>
    <year>2003</year>
    <pub-dates>
      <date>2003</date>
    </pub-dates>
  </dates>
  <abstract>ISO 5167-1:2003 defines terms and symbols and establishes the general principles for methods of measurement and computation of the flowrate of fluid flowing in a conduit by means of pressure differential devices (orifice plates, nozzles and Venturi tubes) when they are inserted into a circular cross-section conduit running full. ISO 5167-1:2003 also specifies the general requirements for methods of measurement, installation and determination of the uncertainty of the measurement of flowrate. It also defines the general specified limits of pipe size and Reynolds number for which these pressure differential devices are to be used. ISO 5167 (all parts) is applicable only to flow that remains subsonic throughout the measuring section and where the fluid can be considered as single-phase. It is not applicable to the measurement of pulsating flow.</abstract>
</record>

<record>
  <contributors/>
  <titles>
    <title>Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full - Part 2: Orifice plates</title>
    <secondary-title/>
  </titles>
  <doi/>
  <pages/>
  <volume/>
  <number/>
  <dates>
    <year>2003</year>
    <pub-dates>
      <date>2003</date>
    </pub-dates>
  </dates>
  <abstract>ISO 5167-2:2003 specifies the geometry and method of use (installation and operating conditions) of orifice plates when they are inserted in a conduit running full to determine the flow-rate of the fluid flowing in the conduit. It also provides background information for calculating the flow-rate and is applicable in conjunction with the requirements given in ISO 5167-1. ISO 5167-2:2003 is applicable to primary devices having an orifice plate used with flange pressure tappings, or with corner pressure tappings, or with D and D/2 pressure tappings. Other pressure tappings such as vena contracta and pipe tappings have been used with orifice plates but are not covered by ISO 5167-2:2003. ISO 5167-2:2003 is applicable only to a flow which remains subsonic throughout the measuring section and where the fluid can be considered as single phase. It is not applicable to the measurement of pulsating flow. It does not cover the use of orifice plates in pipe sizes less than 50 mm or more than 1 000 mm, or for pipe Reynolds numbers below 5 000.</abstract>
</record>


</records>
</xml>