A Monte Carlo Approach to Imaging and Dose Simulations in Realistic Phantoms Using Compact X-Ray Source / Skordis, Eleftherios (U. Liverpool (main) ; CERN) ; Vlachoudis, Vasilis (CERN) ; Welsch, Carsten (U. Liverpool (main) ; Cockcroft Inst. Accel. Sci. Tech.)
X-ray emitters are amongst the most widely used tools in medicine. Based on compact electron beams, they are utilised for a range of applications, including medical imaging and cancer treatment. [...]
2017 - 4 p. - Published in : 10.18429/JACoW-IPAC2017-THPVA137 Fulltext: PDF;

詳細記錄 - 相似記錄
2017-10-14
06:11
ProBE: Proton Boosting Extension for Imaging and Therapy / Pitman, Sam (Lancaster U.) ; Apsimon, Robert (Lancaster U.) ; Burt, Graeme (Lancaster U.) ; Green, Andrew (U. Manchester (main)) ; Grudiev, Alexej (CERN) ; Owen, Hywel (U. Manchester (main)) ; Solodko, Anastasiya (CERN) ; Wuensch, Walter (CERN)
The ProBE linac aims at accelerating protons from a particle therapy cyclotron to the c.330 MeV required for proton tomography. To obtain the c. [...]
2017 - 4 p. - Published in : 10.18429/JACoW-IPAC2017-THPVA135 Fulltext: PDF;

詳細記錄 - 相似記錄
2017-10-14
06:11
Modelling PET Radionuclides Production in Tissue and External Targets Using Geant4 / Amin, Tanjil (Huddersfield U.) ; Barlow, Roger (Huddersfield U.) ; Hoehr, Cornelia (TRIUMF) ; Infantino, Angelo (CERN) ; Lindsay, Clay (TRIUMF)
The Proton Therapy Facility in TRIUMF provides 74 MeV protons extracted from a 500 MeV H⁻ cyclotron for ocular melanoma treatments. During treatment, positron emitting radionuclides such as C-11, O-15 and N-13 are produced in patient tissue. [...]
2017 - 4 p. - Published in : 10.18429/JACoW-IPAC2017-THPVA130 Fulltext: PDF;

詳細記錄 - 相似記錄
2017-10-14
06:11
Preliminary Test Setup of the Metu Defocusing Beam Line, an Irradiation Test Facility in Turkey / Gencer, Aysenur (Middle East Tech. U., Ankara) ; Akçelik, Selen (Middle East Tech. U., Ankara) ; Avaroğlu, Akanay (Middle East Tech. U., Ankara) ; Aydın, Mehmet Serdar (Middle East Tech. U., Ankara) ; Kılıçerkan Başlar, Gamze (Middle East Tech. U., Ankara) ; Bodur, Baran (Middle East Tech. U., Ankara) ; Demirköz, Bilge (Middle East Tech. U., Ankara) ; Efthymiopoulos, Ilias (CERN) ; Kılıç, Ugur (Middle East Tech. U., Ankara) ; Milanese, Attilio (CERN) et al.
METU-Defocusing Beam Line (METU-DBL) Project has been started in August 2015 and aims to construct a beam line at Turkish Atomic Energy Authority Sarayköy Nuclear Education and Research Center Proton Accelerator Facility to perform Single Event Effect (SEE) tests for the first time in Turkey. The METU-DBL is 8m-long and has quadrupole magnets to enlarge the beam size and collimators to reduce the flux. [...]
2017 - 3 p. - Published in : 10.18429/JACoW-IPAC2017-THPVA128 Fulltext: PDF;

詳細記錄 - 相似記錄
2017-10-14
06:11
Open XAL Status Report 2017 / Zhukov, Alexander (ORNL, Oak Ridge (main)) ; Allen, Christopher (ORNL, Oak Ridge (main)) ; Brown, Douglas (NMSU, Las Cruces) ; Chao, Yu-Chiu (SLAC) ; Chu, Chungming (Beijing, Inst. High Energy Phys.) ; Esteban Müller, Juan (ESS, Lund) ; Folsom, Benjamin (ESS, Lund) ; Gillette, P (GANIL) ; Laface, Emanuele (ESS, Lund) ; Laurent, P (GANIL) et al.
The Open XAL accelerator physics software platform is being developed through an international collaboration among several facilities since 2010 The goal of the collaboration is to establish Open XAL as a multi-purpose software platform supporting a broad range of tool and application development in accelerator physics (Open XAL also ships with a suite of general purpose accelerator applications). This paper discusses progress in beam dynamics simulation, interaction with control system and software organization. [...]
2017 - 3 p. - Published in : (2017) , pp. THPVA093 Fulltext: PDF;

詳細記錄 - 相似記錄
2017-10-14
06:11
The Beam Quality Assurance of the MedAustron Particle Therapy Accelerator / Penescu, Liviu (Abstract Landscapes, Montpellier) ; De Franco, Andrea (MedAustron, Wr. Neustad) ; Farinon, Fabio (MedAustron, Wr. Neustad) ; Kronberger, Matthias (MedAustron, Wr. Neustad) ; Kulenkampff, Tobias (CERN) ; Kurfürst, Christoph (MedAustron, Wr. Neustad) ; Myalski, Szymon (MedAustron, Wr. Neustad) ; Nowak, Sebastian (MedAustron, Wr. Neustad) ; Osmić, Fadmar (MedAustron, Wr. Neustad) ; Pivi, Mauro (MedAustron, Wr. Neustad) et al.
The delivery of clinical beams for patient treatment at the MedAustron Ion Therapy Center requires extensive accelerator performance verifications, which are performed in several steps. In first instance, the key parameters of the beam delivered to the irradiation rooms (beam position, spot size, energy and intensity) are verified via measurements performed with beam diagnostic devices distributed along the accelerator. [...]
2017 - 3 p. - Published in : 10.18429/JACoW-IPAC2017-THPVA078 Fulltext: PDF;

詳細記錄 - 相似記錄
2017-10-14
06:11
Overview and Status of the MedAustron Ion Therapy Center Accelerator / Pivi, Mauro (MedAustron, Wr. Neustad) ; De Franco, Andrea ; Farinon, Fabio (MedAustron, Wr. Neustad) ; Kronberger, Matthias (MedAustron, Wr. Neustad) ; Kulenkampff, Tobias (CERN) ; Kurfürst, Christoph (MedAustron, Wr. Neustad) ; Myalski, Szymon (MedAustron, Wr. Neustad) ; Nowak, Sebastian (MedAustron, Wr. Neustad) ; Osmić, Fadmar (MedAustron, Wr. Neustad) ; Penescu, Liviu (Abstract Landscapes, Montpellier) et al.
The synchrotron-based MedAustron accelerator in Wiener Neustadt, Austria, has seen the first clinical beam and has been certified as a medical accelerator in December 2016. This represented a major milestone for the facility whose original design originated more than a decade ago and construction started four years ago. [...]
2017 - 4 p. - Published in : 10.18429/JACoW-IPAC2017-THPVA076 Fulltext: PDF;

詳細記錄 - 相似記錄
2017-10-14
06:11
Beam Measurements in the MedAustron Synchrotron With Slow Extraction and Off-Momentum Operation / Kurfürst, Christoph (MedAustron, Wr. Neustadt) ; De Franco, Andrea (MedAustron, Wr. Neustadt) ; Farinon, Fabio (MedAustron, Wr. Neustadt) ; Garonna, Adriano (TERA, Novara) ; Kronberger, Matthias (MedAustron, Wr. Neustadt) ; Kulenkampff, Tobias (CERN) ; Myalski, Szymon (MedAustron, Wr. Neustadt) ; Nowak, Sebastian (MedAustron, Wr. Neustadt) ; Osmić, Fadmar (MedAustron, Wr. Neustadt) ; Penescu, Liviu (Abstract Landscapes, Montpellier) et al.
The MedAustron Ion Therapy Center is a medical accelerator facility for hadron therapy cancer treatment using protons and carbon ions. The facility features 4 irradiation rooms, three of which are dedicated to clinical operation and a fourth one dedicated to non-clinical research. [...]
2017 - 4 p. - Published in : 10.18429/JACoW-IPAC2017-THPVA075 Fulltext: PDF;

詳細記錄 - 相似記錄
2017-10-14
06:11
Progress in the Bunch-to-Bucket Transfer Implementation for FAIR / Ferrand, Thibault (Darmstadt, Tech. Hochsch.) ; Bachmann, Oliver (Darmstadt, Tech. U.) ; Bai, Jiaoni (Darmstadt, GSI) ; Damerau, Heiko (CERN) ; Klingbeil, Harald (Darmstadt, Tech. Hochsch. ; Darmstadt, GSI)
The transfer of bunched ion beams between various synchrotrons is required for the multi-accelerator complex FAIR, presently under construction at GSI. To avoid a dedicated distribution infrastructure for radiofrequency (RF) signals between each source and destination synchrotron, a new approach has been developed to transmit bunch and bucket phase information using synchronous Ethernet. [...]
2017 - 3 p. - Published in : 10.18429/JACoW-IPAC2017-THPVA041 Fulltext: PDF;

詳細記錄 - 相似記錄
2017-10-14
06:11
Comparison of Different Methods to Calculate Induced Voltage in Longitudinal Beam Dynamics Codes / Quartullo, Danilo (CERN) ; Migliorati, Mauro (Rome U.) ; Repond, Joël (CERN)
Collective effects in longitudinal beam dynamics simulations are essential for many studies since they can perturb the RF potential, giving rise to instabilities. The beam induced voltage can be computed in frequency or time domain using a slicing of the beam profile. [...]
2017 - 4 p. - Published in : 10.18429/JACoW-IPAC2017-THPVA022 Fulltext: PDF;

詳細記錄 - 相似記錄